Under sink or bench unit for the desalination of softened drinking water (free chlorine not detectable), operating using reverse osmosis (RO). Drinking water can also be desalinated without pre-treatment. However, in this case the recovery rate is reduced. The decisive factor is the water analysis.
Unit design
Stainless steel back plate with all the controls mounted.
Special inlet filter with 5 ìm activated carbon filter element,
High pressure pump, high performance spirally wound module with PA/PS composite membranes in stainless steel pressure vessel.
Valves and instruments including solenoid inlet valve,feed water pressure switch, vibration-resistant pressure gauge for pump pressure, flow restrictor for limitation of permeate and concentrate flow rate. Solenoid valve for automatic concentrate rinse.
Microprocessor control system as described below, connecting cable (2 m) with shockproof plug. Unit completely wired and pre-assembled and ready for installation. Electrical equipment in accordance with VDE 0100 part 600, VDE 113 part 1.
*Option: Permeate conductivity measurement (item no 391 903)
RO 524 microprocessor control system for fully automated monitoring and control of the reverse osmosis unit with two-digit alphanumeric display of permeate conductivity*, forced stop and full tank, malfunction signals: low pressure, hard water and high conductivity*, automatic restart of operation after progressive rest period, LEDs for operation and disinfection, concentrate flushing each operating cycle, forced flushing after 24 h standby
Additional connections possible:
Inputs (low voltage) for level control with 1 or 2 float switches, hardness monitoring unit (the RO 524 controller includes control functions for the limitron hardness monitoring unit), shut-downs by external signal (forced stop, regeneration).
Outputs for softening unit (230 V / 50 Hz) and DDC (collective malfunction signal on floating change-over contact).
The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a max. colloidal index of 3 and free permeate outlet. Under these conditions, the unit reaches design permeate flow. The permeate recovery depends on the raw water quality and the type of pre-treatment.
Technical Data
Permeate flow rate : 130 l/hr (at 15°C), 100 l/hr at 10°C
Min. Salt rejection: 95%
Revovery: 50%
Operating pressure (approx.): 10 bar
Membrane: one 4" x 21"
Voltage: 230 V, 50 Hz
Motor pwer: 0.4 KW
Pre-fusing: 16A
Feedwater connection: 3/4"
Permeate/waste connection: 10mm
Min/max feed water pressure: 3 bar / 6 bar
Max. ambient feedwater temperature: 40°C
pH: 3 - 11
Height/width/depth: 370 mm / 800 mm/ 370mm
Weight (approx.): 31 kg